High Accuracy True RMS multimeter System Multimeter
GST inclusive price for Australian Customers is AUD$951.50
5 1/2 Digit High Accuracy 120,000 Count Dual Display Bench DMM
120,000 / 40,000 / 4,000 Count Display. Resolution Selectable
120ppm Basic DCV Accuracy
Dual Digital, Multi-function Vacuum Fluorescent Display (VFD)
Measurement Rate Selectable with Slow: 2/Sec (120,000), Medium: 5/Sec (40,000), and Fast: 20/Sec (4,000)
DCV Range from 120mV to 1,000V with 1µV Best Resolution
ACV Range from 120mV to 750V with 1µV Best Resolution
DCA and ACA Ranges 12mA, 120mA, and 12A with 100nA Best Resolution
TRUE RMS AC and AC+DC Measurement, ACV 40Hz-30 kHz, and ACA
45Hz-5kHz Bandwidth
Resistance Measurement Range from 120 ohm to 300 Megohm with 1milliohm Best Resolution
2-wire / 4-wire Resistance Measurement Selectable
Frequency Measurement Range from 1200Hz to 1MHz with 0.01Hz Best Resolution
dBm Measurement with 0.01dBm Resolution and Reference Impedance from 2 ohm to 8000 ohm
Auto or Manual Ranging
Data Hold Function to Freeze Displayed Readings
Relative Mode for Zeroing Offset
Dynamic Min / Max Recording
Compare (Hi / Lo / Pass) Function for Quick In-Tolerance Tests
Fast Electronic and Closed-Case Calibration
Rugged Design with Protective Holsters
Standard RS-232 Interface
Optional GPIB Interface (conform to SCPI and IEEE-488.2 standards)
Meets IEC-1010-1 600V CAT II and 1000V CAT I and CE Mark
GST inclusive price for Australian Customers is AUD$779.90
5 1/2 Digit 120,000 Count Dual Display Bench DMM
120,000 / 40,000 / 4,000 Count Display Resolution Selectable
200ppm Basic DCV Accuracy
Dual Digital, Multi-function Vacuum Fluorescent Display (VFD)
Measurement Rate Selectable with Slow:
2/Sec (120,000),Medium: 5/Sec (40,000), and Fast: 20/Sec (4,000)
DCV Range from 120mV to 1,000V with 1µV Best Resolution
ACV Range from 120mV to 750V with 1µV Best Resolution
DCA and ACA Ranges 12mA, 120mA, and 12A with 100nA Best Resolution
TRUE RMS AC and AC+DC Measurement, ACV 40Hz-30 kHz, and ACA 45Hz-5kHz Bandwidth
Resistance Measurement Range from 120 ohm to 300MegOhm with 1milliohm Best Resolution
2-wire / 4-wire Resistance Measurement Selectable
Frequency Measurement Range from 1200Hz to 1MHz with 0.01Hz Best Resolution
dBm Measurement with 0.01dBm Resolution and Reference Impedance from 2 ohm to 8000 ohm
Auto or Manual Ranging
Data Hold Function to Freeze Displayed Readings
Relative Mode for Zeroing Offset
Dynamic Min / Max Recording
Compare (Hi / Lo / Pass) Function for Quick In-Tolerance Test
Fast Electronic and Closed-Case Calibration
Rugged Design with Protective Holsters
Standard RS-232 Interface
Optional GPIB Interface (conform to SCPI and IEEE-488.2 standards)
Meets IEC-1010-1 600V CAT II and 1000V CAT I and CE Mark
GST inclusive price for Australian Customers is AUD$539.00
Low Cost and High Performance Bench DMM
50,000 Count Display Resolution with Readable Full Scale 51,000 Counts
Dual Digital, Multi-function Vacuum Fluorescent Display (VFD)
200ppm Basic DCV Accuracy
DCV range from 500mV to 1000V with 10microvolt Best in Resolution, Measurable DCV up to 1200V Maximum 1000V Range with Audible Warning
ACV range from 500mV to 750V with 10microvolt Best Resolution, Measurable ACV up to 1000V Maximum in 750V Range with Audible Warning
DCA and ACA in 6 Ranges from 500 microamp to 5A, and 20A with 10nA Best Resolution
TRUE RMS AC and AC+DC measurement, ACV 30Hz-100 kHz, and ACA 30Hz-20kHz Bandwidth
2-wire Resistance measurement range from 500 ohm to 50 Megohm with 10 milliohm Best resolution
dBm Measurement with 0.01dBm Resolution and Reference Impedance from 2 ohm to 8000 ohm
Frequency Measurement Range from 500Hz to 500kHz with 0.01Hz Best Resolution
Diode and Audible Continuity Test
Auto or Manual Ranging
Data Hold Function to Freeze Displayed Reading
Refresh Hold for Difficult Measurement Environment
Relative Calculation for Zeroing Offset
Dynamic MIN / MAX Recording with Elapsed Time
Compare (Hi / Lo / Pass) Function for Quick In-Tolerance Tests
Percentage Function to Transfer Measured Value to Proportional Percentage (%) Reading
External Trigger for One-Time Measurement to Get Readings as You Need
Fast Electronic and Closed-Case Calibration
Rugged Design with Protective Holsters
Standard RS-232 Interface
Optional GPIB Interface (conform to SCPI and IEEE-488.2 standards)
Meets IEC-1010-1 600V CAT II and 1000V CAT I and CE Mark