Yokogawa
 |
| AC/DC Current 40/300A |
| |
|
GST inclusive price for Australian Customers is AUD$363.00 |
| |
| |
| |
|
Clamp-on AC/DC Current Tester
- Light weight & compact design
- Mean value display
- AC/DC Current: 40/300A ranges.
- 24mm in diameter of measurable conductor
- Sleep function
- Approved for conformity to safety standards EN61010-1, EN61010-2-032 (CAT. III 300 V)
Accuracy
DC Current
40A 1.0% + 4
300A (±20 ~ ±200A) 1.5% + 4
300A (±200 ~ ±300A) 3.0%
AC Current
40A (20 ~ 200A) 1.0%+4(50/60Hz), 2.5%+4(20~1kHz)
300A (20 ~ 200A) 1.5%+4(50/60Hz) , 2.5%+4(10~1kHz)
300A (200 ~ 300A) 3.5% (50/60Hz) , 4.0% (20~1kHz
SPECIFICATION:
Method of Detection Mean Value
Diameter of Measurable conductor Ø24MM at maximum
Display LCD (Digital Display: 3999 Counts)
Response Time (Approx.) 2 Seconds
Range Switching Auto-Range Data Hold On All range
Ambient Temperature and Humidity 0-40°C, 85% RH or less (no condensation)
Influence of external Magnetic Field 1A or less at 400 A/m
Influence of Conductor Position ±(2% rdg + 5dgt)or Less
Circuit Voltage 300Vrms or less
Withstanding Voltage 3.7kV AC for one minute
Power Supply LR-44 x2(3V) or SR-44 x2
Battery Life Approx. 11 hours (continuous)
Consumed Current Approx. 9mA
Sleep Function Automatically powered down in about 5 minutes after last switch operation
Dimensions Approx. 59(W)x147(H)x25(D)mm
Weight Approx. 100g
|
 |
| Large Jaw Size |
| |
|
GST inclusive price for Australian Customers is AUD$825.00 |
| |
| |
| |
|
Clamp-on AC/DC Current Tester
True RMS Method of Detection
AC/DC current measurements with current ranges up to 600A for AC & 1000A for DC.
AC/DC voltage, resistance and frequency measurements.
33mm in diameter of measurable conductor
Sleep Function. Data Hold Function.
Approved for conformity to safety standard EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V)
Accuracy
AC Current 400A/600A 1.5+5 (50/60Hz) 3.5+5 (40~1kHz)
DC Current 400A/1000A 1.0+5
AC Current 40/400A/600V 1.5+5 (50/60Hz) 3.5+5 (40~1kHz)
Crest Factor =3 Resistance 400/4000O 1.0+5, Beeps at below 20O (Continuity check)
Resistance 10 ~ 3000Hz 1.5+5
Specification
Method of Detection True RMS
Diameter of Measurable conductor Ø33MM at maximum
Display LCD (Digital Display: 3999 Counts)
Response Time (Approx.) 2 Seconds
Range Switching Auto-Range Data Hold On All range
Peak Hold On AC/DC Current Range; AC/DC Voltage Range
Ambient Temperature and Humidity 0-40°C, 90% RH or less (no condensation)
Influence of external Magnetic Field - Influence of Conductor Position ±2% or Less
Circuit Voltage 600Vrms or less Withstanding Voltage 5.55kV AC for one minute
Power Supply 6F22(006P) x1; or 6LR61 x 2
Battery Life Approx. 15 hours (continuous)
Consumed Current Approx. 15mA
Sleep Function Automatically powered down in about 30 minutes after last switch operation
Dimensions Approx. 91(W)x210(H)x40(D)mm
Weight Approx. 450g
|
|