Reed Calibrators
Reed CC-421 Voltage/Current Calibrator | $478.00
|
 |
| Voltage/Current Calibrator |
| |
|
GST inclusive price for Australian Customers is AUD $525.80 |
| |
| |
| |
|
CALIBRATOR, VOLTAGE/CURRENT, DUAL RANGE
- Source and measure voltage and current
- Current calibrator drives loads up to 500O
- 13mm LCD display
- Includes test leads
SPECIFICATIONS:
Current Source: 0 to 24 mA (2 ranges)
Current Measure: 0 to 24 mA (2 ranges)
Voltage Source: -199.9 to +199.9 mV DC
Dimensions: 185 x 78 x 38mm
Weight: 265g
|
 |
| Current Loop Calibrator |
| |
|
GST inclusive price for Australian Customers is AUD $437.80 |
| |
| |
| |
|
CURRENT LOOP CALIBRATOR, 0-24 mA
- Adjustable 0 to 24mA current source, 2 ranges
- Current calibrator drives loads up to 500O
- 13 mm LCD display
- Includes test leads
SPECIFICATIONS:
Range: 0 to 19.99 mA; 0 to 24.0 mA
Resolution: 0.01 mA; 0.1 mA
Sampling Time: 0.4 second
Dimensions: 185 x 78 x 38mm
Weight: 265g
|
Reed VC-01 Temperature Simulator | $530.00
|
 |
| Temperature Simulator |
| |
|
GST inclusive price for Australian Customers is AUD $583.00 |
| |
| |
| |
|
Temperature Simulator
- Provides a quick and easy way for checking the calibration of Thermocouples
- Includes test leads, soft carrying case and batteries
Specifications
Voltage Range/Resolution:
-10.00 to 110.00mV/0.01mV;
-100.00 to 1100.0mV/0.1mV
Resistance Range/Resolution:
0.0 to 400.0 ohms/0.1 ohm
Thermocouple Range
Resolution: R:-40 to 1760°C/1°C
S:-20 to 1760°C/1°C
B: 400 to 1800°C/1°C
E: -200.0 to 1000.0°C/ 0.1°C
K: -200.0 to 1370.0°C/0.1°C
J: -200.0 to 1200.0°C/0.1°C
T: -200.0 to 400.0°C/0.1°C
N: -200.0 to 1300.0°C/0.1°C
Thermo-resistance
Range/Resolution: Pt100: -200.0 to 850.0°C/0.1°C
Cu50: -50.0 to 150.0°C/0.1°C
Accuracy: ±0.05% setting value
|
Reed VC04 Voltage/Current Simulator | $530.00
|
 |
| Voltage/Curent Simulator |
| |
|
GST inclusive price for Australian Customers is AUD $583.00 |
| |
| |
| |
|
Voltage/Current Simulator:
- Combines Voltage and Current Source and Read Functions into One Instrument.
- Combines voltage and current source and read functions
- 5-digit LCD readout
- ±0.05% accuracy
- Automatic calibration
- User selectable auto power-off
- Includes test leads, soft carrying case and batteries
SPECIFICATIONS:
Output function
Voltage Range: 10V
Output Range: 0.00 to 11.000V
Resolution: 1mV
Accuracy: ±0.05% setting
Current Range: 20mA
Output Range: 0.000 to 22.000mA
Resolution: 0.001mA
Accuracy: ±0.05% setting + 4µA
Analogue Transducer: -20mA
Output Range: 0.000 to -22.000mA
Resolution: 0.001mA
Accuracy: ±0.05% setting + 4µA
Loop Power: 24V
Accuracy: ±10%
Power Supply: Single 9V alkaline battery
Battery Life: Approx. 20 hours
Ambient Conditions: -10 to 55°C; = 80% RH
Dimensions: 200 x 100 x 40mm with protective holster
Weight: 550g w/ holster
|
Reed VC05 Current Loop Calibrator | $595.00
|
 |
| Current Loop Calibrator |
| |
|
GST inclusive price for Australian Customers is AUD $654.50 |
| |
| |
| |
|
LOOP CALIBRATOR
- mA sourcing, simulation and measurement
- 0-28 VDC measurement to check loop voltage
- 0.02% accuracy and 0.001% of span display
- Simulate mA and % of span display
- Selectable step or ramp outputs
- 24V loop power supply
- Includes test leads, soft carrying case & batteries
SPECIFICATIONS:
Output function
Current Range: 0.000 to 22.000mA
Resolution: 0.001mA
Accuracy: ±0.05% ±4µA
Loop Power Range: 24V
Accuracy: ±10%
measurement function
Voltage Range: -0.200 to 28.000V
Resolution: 1mV
Accuracy: ±0.02% rdg. ±2mV
Current Range: -1.000 to 22.000mA
Resolution: 0.001 mA
Accuracy: ±0.02% rdg. ±4µA
Loop Current Range: 0.000 to 22.000mA
Resolution: 0.001 mA
Accuracy: ±0.02% rdg. ±4µA
Power Supply: Single 9V battery
Battery Life: Approx. 12 hours
Dimensions/Weight: 200 x 100 x 40mm/550g
|
Reed VC14 Temperature Calibrator | $1190.00
|
 |
| Temperature Calibrator |
| |
|
GST inclusive price for Australian Customers is AUD $1,390.00 |
| |
| |
| |
|
TEMPERATURE CALIBRATOR
- Automatic cold-end temperature offset
- 2-wire/3-wire/4-wire connectionis user-selectable
- 6-digit LCD readout
- ±0.02% accuracy
- Automatic calibration
- User selectable auto power-off
- Includes test leads, soft carrying case and batteries
SPECIFICATIONS:
output function
Voltage Range/Resolution: -10.000 to 110.000mV/10µV; -0.10000 to 1.10000V/0.01mV
Resistance Range/Resolution:
0.00 to 400.00 ohm/00.1 ohm
Thermocouple Range/Resolution: R: -40 to 1760°C/1°C; S: -20 to 1760°C/1°C; B: 400 to 1800°C/1°C; E: -200.0 to 1000.0°C/ 0.1°C; K: -200.0 to 1370.0°C/0.1°C; J: -200.0 to 1200.0°C/0.1°C; T: -200.0 to 400.0°C/0.1°C; N: -200.0 to 1300.0°C/0.1°C
Thermo-resistance Range/Resolution: Pt100: -200.0 to 850.0°C/0.1°C; Cu50: -50.0 to 150.0°C/0.1°C
measurement function
Voltage Range/Resolution: 0.00 to ±450.00mV/10µV
Resistance Range/Resolution: 0.00 to 450.00O/00.1O
Thermocouple & Thermo-resistance Range: Same as per Output Function
|
Reed VC15 Voltage & Current Calibrator | $1190.00
|
 |
| Voltage & Current Calibrator |
| |
|
GST inclusive price for Australian Customers is AUD $1,390.00 |
| |
| |
| |
|
VOLTAGE & CURRENT CALIBRATOR
- 6-digit LCD readout
- Auto calibration
- Auto power off
- Includes test leads, soft carrying case & batteries
SPECIFICATIONS:
Output function
Voltage Range: 0.000 to 11.000V
Resolution: 0.1mV
Accuracy: ±0.02% rdg. ±0.01% range
Current Range: 0.000 to 22.000mA
Resolution: 0.001 mA
Accuracy: ±0.05% ±0.01% range
Loop Power Range: 24V
Accuracy: ±10%
Measurement function
Voltage Range: 0.000 to 11.000V
Resolution: 1mV
Accuracy: ±0.02% rdg. ±0.01% range
Current Range: 0.000 to 22.000mA
Resolution: 0.001 mA
Accuracy: ±0.02% rdg. ±0.01% range
Loop Current Range: 0.000 to 22.000mA
Resolution: 0.001 mA
Accuracy: ±0.02% rdg. ±0.01% range
Power Supply: Single 9V battery
Battery Life: Approx. 12 hours
Dimensions/Weight: 200 x 100 x 40mm/550g
|
|