Yokogawa Calibrators
 |
| Process Calibrator with milliamps & Voltage |
| |
|
GST inclusive price for Australian Customers is AUD$1424.50 |
| |
| |
| |
|
Voltage / Current Calibrator.
- CA11E Handy Cal - Voltage/ Loop Current Calibrator
- Both signal source and measurement functions
- Basic Accuracy 0.005%
- Simple operation, easy to use
- Lightweight, compact body
- Display resolution for current 0.001mA
- Addition of loop check function
- Addition of rubber boot as accessory
Source and Measuring of Voltage and Current
Generates and measures voltages up to 30 V DC and currents up to 24 mA DC. Improved display resolution for current
The generation/measurement resolution has improved to 0.001 mA 24 V (20 mA)/Loop check function up to DC22 mA
Enables measurement of generated current signals while supplying loop power to two-wire transmitter. 20 mA SINK Function
Absorbs the voltage supplied from an external power supply to its H terminal and simulates a two-wire transmitter making it ideal for loop checks. Sweep Function
Increases and decreases the output level to the preset level at a constant rate for the selected sweep time (16 or 32 seconds). The sweep function and sweep time are set by the internal dip switches. Power Switch Up/Down Keys
Used to set the output signal level. A pair of up/down keys is conveniently located immediately below each digit in the LCD panel.
Output On/Off Switch (Output signal can set ON/OFF) Range Selection Rotary Switch
The rotary switch simplifies range selection: just leave the switch set to the most frequently used range. Source/Measure Selection Switch
|
 |
| Temperature Calibrator for Thermocouples & RTD's |
| |
|
GST inclusive price for Australian Customers is AUD$1424.50 |
| |
| |
| |
|
CA12E Temperature / Thermocouple / RTD
Calibrator
The Yokogawa CA12E temperature calibrator has an output equivalent to ten types of thermocouples: K, E, J, T, N, R, U, L, B, and S as well as Pt100 resistance temperature detector. (The former Pt100 standard, JPt100, is also selectable by an internal dip switch.)
The Yokogawa CA12E temperature calibrator is suitable for a broad range of applications such as maintenance of industrial process instruments and various thermometers. With a three-wire RTD connection, the Yokogawa CA12E temperature calibrator can also be used as a precision, multi-range thermometer. Featuring a built-in sensor for reference junction compensation, the Yokogawa CA12E temperature calibrator also has a terminal adapter which provides screw terminals for connecting a temperature sensor such as a thermocouple and RTD when measuring temperature.
The Yokogawa CA12E temperature calibrator ships complete with calibrator, one pair lead cables, terminal adapter, battery and instruction manual.
|
 |
| Multi-Function Calibrator |
| |
|
GST inclusive price for Australian Customers is AUD$2,337.50 |
| |
| |
| |
|
Yokogawa CA71 Handy CAL Calibrator
Multifunction calibrator simultaneously generates and measures voltage, current, TC, RTD, and pulse signals
Sensors and instruments require a wide variety of operation checks in the field. The Yokogawa CA71 Handy CAL calibrator is a small, lightweight, multifunction calibrator that can simultaneously source and measure voltage, current, resistance, TC, RTD, frequency, and pulse signals. By itself, the Yokogawa CA71 Handy CAL calibrator can source signals for input to equipment and check output signal from equipment.
The Yokogawa CA71 Handy CAL calibrator incorporates rotary switches for simple handling. Just open the carrying case cover and connect the cables, and you're ready to take measurements.
A wide array of useful functions
Functions available to the multifunction Yokogawa CA71 Handy CAL calibrator include divided output (n/m) function, auto-step function, sweet function, memory function, and communication function.
Source: Values set in steps of 4-20 mA 24V DC Power Supply to Transmitter
Divided output (n/m) function: Output settings are divided, eliminating the need for bothersome calculations for percentage output.
Autostep function: Changes the output value in step form based on the setting from the divided output (n/m) function. Changes can be sourced automatically every 10% or 25%.
Online communication: RS-232C-compliant optically isolated interface
Sweep function: Linearly increases or decrease the output. The increasing / decreasing time can be set to either 16 or 32 seconds.
Memory function: Source values and measurements forming individual value sets can be saved to or read from the Handy Calibrator's internal memory (maximum 50 value sets).
Temperature monitor function
AC voltage (including supply voltage) measurement capability
In cases where numerous signal converters and other devices are mounted on a rack or panel, the multifunction Yokogawa CA71 Handy CAL calibrator can be used to check the input and output signals of each device while simultaneously checking the power supply. There is no need for a separate multimeter to measure supply voltage.
|
|