Fluke Infra-red Thermometers
 |
| * New from Fluke * HIGH Specification LOW Price |
| |
|
GST inclusive price for Australian Customers is AUD$220.00 |
| |
| |
| |
|
Now Introducing the Fluke 62 Mini!
This compact and portable tool enables professionals to diagnose heating and ventilation problems and monitor the temperature of electrical motors and electrical panels without contact.
Rugged enough for industrial environments with its protective rubber “boot”, the 62 Mini also comes with a handy nylon holster, keeping quick temperature checks at your fingertips.
FEATURES
Single point offset laser sighting
Best accuracy in its class: + 1% of reading
Holds temperature readings for 7 seconds
Dual displays shows current and MAX measurements simultaneously
Backlit display for poorly lit areas
Comfortable ergonomic handle with protective rubber boot for added durability
Fitted carrying case
Robust, award winning design
Wide temperature range from -30º to 500ºC
|
 |
| The ideal professional diagnostic tool |
|
GST inclusive price for Australian Customers is AUD$445.50 |
| |
| |
| |
| |
|
The Fluke 63 non-contact thermometer is the ideal professional diagnostic tool for quick and accurate temperature measurements. This handheld portable tool enables professionals to research heating and ventilation problems, monitor the status of electrical motors and electrical panels and diagnose car malfunctions with ease.
The Fluke 63 thermometer makes troubleshooting quick and easy. The single dot laser sighting system guides measurements to the right target and in less than a second, the large temperature display provides current and MAX surface temperatures. The locking trigger and tripod mount capability allow for continuous temperature monitoring.
Backlit display for poorly lit areas
Holds temperature readings
Enhanced optics (distance to spot ratio up to 12:1) allow you to measure smaller objects from farther away
Displays Max measurements
Adjustable emissivity setting for more accurate measurements
Rugged rubber overmolding
Durable plastic storage case
Specifications
Temperature range: -32 °C to 535 °C (-25 °F to 999 °F)
Distance to Spot size: 12:1
Laser sighting: Single point, offset
Emmissivity: Pre-set to 0.95
Accuracy: + 1% of reading or +1 °C (+2 °F), whichever is greater
Response time: 500 mSec
Weight/Dimensions: 320g (11 oz) 200 x 160 x 55 mm (8 x 6 x 2 in)
Power: 9V Alkaline Battery
Battery Life (Alkaline): 10 hrs. w/laser & backlight on 20 hrs. w/laser and backlight off
Display Hold: 7 seconds
Warranty: 1 year
|
 |
| Ideal for the HVAC Professional |
| |
|
GST inclusive price for Australian Customers is AUD$363.00 |
| |
| |
| |
|
Features & Applications:
Lighten up your toolbox with the one tool that combines the temperature measurement functions that professionals need most for inspecting heating, ventilation, air conditioning and refrigeration systems. The Fluke 561 HVACPro provides both non-contact and contact temperature measurements, replacing several other test tools. It is fast, efficient and easy to use, saving you valuable time and effort.
Features laser-guided sighting for IR measurements!
In the IR mode, you can take temperatures within two meters of the target and scan ducts from further away without a ladder. The laser sighting system guides measurements. The single laser dot indicates the approximate center of the measurement area. The measured area becomes larger with distance.
Features:
Use the infrared (IR) thermometer to measure hot, moving, electrically energized and hard-to-reach objects instantly
Check motors, insulation, breakers, radiant heating, pipes, corroded connections and wires plus scan ducts in the ceiling from the floor without a ladder
Handy Velcro pipe probe included for superheat and sub-cooling contact measurements
Or plug in your own industry-standard K-type thermocouple probes and get the most out of your tool investments
IR thermometer for quick measurements up close or at a distance, without a ladder
Compatible with all standard mini-connector K-type thermocouples
Velcro pipe probe for superheat, sub-cooling or other contact and ambient measurements
Single-point laser sighting
Temperature range optimized for HVAC/R applications
Easy emissivity adjustment for measuring pipes and ducts more accurately
Lightweight (only 340 grams (12 ounces) and portable
Very easy to use
Efficient – no need to shut down equipment when making IR measurements
MIN, MAX and DIF temperature readings help you quickly identify problems
Scan large areas or small objects quickly and efficiently
HVAC/R measurement guide included to maximize your productivity
Specification Summary:
Temperature: -40 to 1022°F (-40 to 550°C)
Display Resolution: 0.1°F (0.1°C) of reading
D:S (Distance to spot size): 12:1
Easy Emissivity Selector: Adjustable with three settings:
Low (0.3), Medium (0.7). High (0.95)
Display Accuracy
Assumes ambient operating temperature of
73°F (23°C) to 77 °F(25°C)]: ±1.0 % of reading ±1 % of reading or
±2°F (±1°C), whichever is greater below
32°F/0°C, ±2°F (±1°C) ± 0.1°/1°
Response Time: 500 mSec (95 % of reading)
Repeatability: ±0.5 % of reading or ±2°F (±1°C),
whichever is greater
Spectral Response: 8 µm to 14 µm
Laser Sighting: Single point laser
Laser Shutoff: Laser turns off above ambient temperature of 104°F (40°C)
Laser Power: Class 2(II) operation; Output less than 1 mW wavelengh 630-670 nm
Relative Humidity: 10 to 90 % RH non-condensing, at less than86°F (30°C)
Power: 2 AA batteries (alkaline or NiCD)
Battery Life: 12 hours
Display Hold: 7 seconds
Backlit Display: Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC),
low battery, F/C indicator, and Scan/Hold options
Warranty: 2 years
Operating Temperature: 32 to 120 °F (0 to 50 °C)
Storage Temperature: -25 to 150 °F (-20 to 65 °C)
Thermocouple Type K Mini Adapter Input: Yes, compatible with industry standard K type probes with
mini-connector.
Thermocouple Type K Velcro Pipe Probe: Yes, with a temperature range of 32 to 212°F (0 to 100°C)
and accuracy of ±4°F (±2.2°C)
|
 |
| |
| |
|
GST inclusive price for Australian Customers is AUD$726.00 |
| |
| |
| |
|
Features & Applications:
With a simple, 3-button on-screen menu interface (in 6 languages), the Fluke 566 Infrared and Contact Thermometer makes even complex measurements easy. Quickly navigate advanced features to adjust emissivity, start data logging, or turn on and off alarms - with just a few pushes of a button. It also has a rugged, easy-to-use, ergonomic design, which allows it to stand up to tough industrial, electrical and mechanical environments.
Features:
Measure -40 °C to 650 °C/-40 °F to 1202 °F
Easily access advanced features with the soft-key buttons and dot-matrix display
Measure smaller objects from further away, with a distance-to-spot ratio of 30:1
Compatibility with all standard miniconnector Type-K thermocouples allow you to preserve your thermocouple investments
Confidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table
Capture multiple points of data (up to 20), for downloading and recalling later
Easily adapt to lighting conditions with 2 levels of backlight
Audible and visual alarms instantly alert you to measurements outside of your set limits
Quickly identify problems with the MIN, MAX, AVG, and DIF functions
Make contact thermometer measurements right away with the included Type-K thermocouple bead probe
Confidently troubleshoot equipment with 1 % measurement accuracy
Versatile interface with 6 languages from which to choose (English, Spanish, French, German, Portuguese and Simplified Chinese)
Includes:
Thermocouple K bead probe
Durable hard case
2 AA batteries
Getting Started guide in 6 languages
User’s Manual on CD in 6 languages
2-year warranty
Specification Summary:
Infrared Temperature Range: -40 °C to 650 °C (-40 °F to 1202 °F)
Infrared Accuracy: less than 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F);
greater than 0 °C (32 °F): ± 1 % or ± 1.0 °C (± 2.0 °F), whichever is greater
Display Resolution: 0.1 °C / 0.1 °F Infrared Spectral Response: 8 µm to 14 µm
Infrared Response Time: less than 500 msec
Thermocouple Type-K Input Temperature Range: -270 °C to 1372 °C (-454 °F to 2501 °F)
Thermocouple Type-K Input Accuracy:
-270 °C to -40 °C: ± (1 °C + 0.2 °/1 °C) (-454 °F to -40 °F: ± (2 °F + 0.2 °/1 °F
-40 °C to 1372 °C: ± 1 % or 1 °C (-40 °F to 2501 °F: ± 1 % or 2 °F), whichever is greater
D:S (Distance to measurement spot size: 30:1
Laser Sighting: Single-point laser less than 1 mw output Class 2 (II) operation, 630 nm to 670 nm Minimum Spot Size: 19 mm Emissivity Adjustment: By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage w/ Date/Time Stamp: 20 points
PC Interface and Cable:
None Hi/Low Alarms: Audible and two-color visual
Min/Max/Avg/Dif: Yes
Display: Dot matrix 98 x 96 pixels with functions menus
Backlight: Two levels, normal and extra bright for darker environments
Trigger Lock: Yes
Switchable Celsius and Fahrenheit: Yes
Power: 2AA/LR6 batteries
Battery Life: If used continuously: laser and backlight on, 12 hours; laser and backlight off, 100 hours
Operating Temperature: 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature: -20 °C to 60 °C (-40 °F to 140 °F)
Bead Thermocouple Type-K Range: -40 °C to 260 °C (-40 °F to 500 °F)
Bead Thermocouple Type-K Accuracy: ± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F), typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)
|
 |
| |
| |
|
GST inclusive price for Australian Customers is AUD$957.00 |
| |
| |
| |
|
Just when you thought advanced IR temperature measurement should be easier, Fluke meets the demands of it's customers with this new line of Thermometers. With a straight-forward user interface and soft-key menus, the Fluke 568 make even complex measurements easy. Quickly navigate and adjust emissive, start data logging, or turn on and off alarms, with just a few pushes of a button. With a rugged, easy-to-use, ergonomic design, the Fluke 568 can stand up to tough industrial, electrical, and mechanical environments
Features
Measure -40 °C to 800 °C/-40 °F to 1472 °F
Easily access advanced features with the soft-key buttons and graphical display
Measure smaller objects from further away, with a distance-to-spot ratio of 50:1
Compatibility with all standard mini-connector K-type thermocouples allows you to preserve your thermocouple investments
Confidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table
Capture up to 99 point of data, for downloading and recalling later
Easily trend and analyze data with included FlukeView® Forms software
See your data right away without leaving the site, using the USB and your laptop for "Hands-free" data logging
Confidently troubleshoot equipment with 1 % measurement accuracy
Versatile interface with six languages from which to choose
Specifications
Infrared temperature range : -40 °C to 800 °C
Infrared accuracy: Less than 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F) , greater than 0 °C (32 °F): ± 1 % or ± 1.0 °C (± 2.0 °F), whichever is greater
Display resolution 0.1 °C / 0.1 °F
Infrared spectral response: 8 µm to 14 µm
Infrared response time: Less than 500 msec
Thermocouple Type-K input temperature range: -270 °C to 1372 °C (-454 °F to 2501 °F)
input accuracy -270 °C to -40 °C: ± (1 °C + 0.2 °/1 °C) (-454 °F to -40 °F: ± (2 °F + 0.2 °/1 °F)) -40 °C to 1372 °C: ± 1 % or 1 °C (-40 °F to 2501 °F: ± 1 % or 2 °F), whichever is greater
D:S (distance to measurement spot size) 50:1
Laser sighting Single-point laser less than 1 mw output Class 2 (II) operation, 630 nm to 670 nm
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage with Date/Time stamp 99 points
Hi/Low alarms Audible and two-color visual Min/Max/Avg/Dif Yes
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage temperature -20 °C to 60 °C (-40 °F to 140 °F)
Bead thermocouple Type-K Range -40 °C to 260 °C (-40 °F to 500 °F) accuracy ± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F), typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)
Display Dot matrix 98 x 96 pixels with function menus
PC Interface and cable USB 2.0 with FlukeView® Forms software
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable Celsius and Fahrenheit Yes
Power 2 AA/LR6 Batteries USB when used with a PC
Battery life If used continuously: laser and backlight on,12 hours; laser and backlight off, 100 hours
|
|