Temperature & Humidity
Thermocople Thermomters
Infra-red Thermometers
Fluke
Reed
Extech
Temperature Data Loggers
Humidity
Thermo Hygrographs
Food Service (HACCP)

 

 

 

Back
Fluke Infra-red Thermometers


    Fluke 62 $200.00

    Fluke 62
      * New from Fluke *
      HIGH Specification
      LOW Price


      GST inclusive price for Australian Customers is AUD$220.00

      Remove from Cart Add to Cart


    Now Introducing the Fluke 62 Mini!

    This compact and portable tool enables professionals to diagnose heating and ventilation problems and monitor the temperature of electrical motors and electrical panels without contact.
    Rugged enough for industrial environments with its protective rubber “boot”, the 62 Mini also comes with a handy nylon holster, keeping quick temperature checks at your fingertips.
    FEATURES
    Single point offset laser sighting
    Best accuracy in its class: + 1% of reading
    Holds temperature readings for 7 seconds
    Dual displays shows current and MAX measurements simultaneously
    Backlit display for poorly lit areas
    Comfortable ergonomic handle with protective rubber boot for added durability
    Fitted carrying case
    Robust, award winning design
    Wide temperature range from -30º to 500ºC



    Fluke 63 $405.00

    Fluke 63
      The ideal professional diagnostic tool


      GST inclusive price for Australian Customers is AUD$445.50

      Remove from Cart Add to Cart


    The Fluke 63 non-contact thermometer is the ideal professional diagnostic tool for quick and accurate temperature measurements. This handheld portable tool enables professionals to research heating and ventilation problems, monitor the status of electrical motors and electrical panels and diagnose car malfunctions with ease.

    The Fluke 63 thermometer makes troubleshooting quick and easy. The single dot laser sighting system guides measurements to the right target and in less than a second, the large temperature display provides current and MAX surface temperatures. The locking trigger and tripod mount capability allow for continuous temperature monitoring.
    Backlit display for poorly lit areas
    Holds temperature readings
    Enhanced optics (distance to spot ratio up to 12:1) allow you to measure smaller objects from farther away
    Displays Max measurements
    Adjustable emissivity setting for more accurate measurements
    Rugged rubber overmolding
    Durable plastic storage case

    Specifications
    Temperature range: -32 °C to 535 °C (-25 °F to 999 °F)
    Distance to Spot size: 12:1
    Laser sighting: Single point, offset
    Emmissivity: Pre-set to 0.95
    Accuracy: + 1% of reading or +1 °C (+2 °F), whichever is greater
    Response time: 500 mSec
    Weight/Dimensions: 320g (11 oz) 200 x 160 x 55 mm (8 x 6 x 2 in)
    Power: 9V Alkaline Battery
    Battery Life (Alkaline): 10 hrs. w/laser & backlight on 20 hrs. w/laser and backlight off
    Display Hold: 7 seconds
    Warranty: 1 year



    Fluke 561 $330.00

    Fluke 561
      Ideal for the
      HVAC Professional


      GST inclusive price for Australian Customers is AUD$363.00

      Remove from Cart Add to Cart


    Features & Applications:
    Lighten up your toolbox with the one tool that combines the temperature measurement functions that professionals need most for inspecting heating, ventilation, air conditioning and refrigeration systems. The Fluke 561 HVACPro provides both non-contact and contact temperature measurements, replacing several other test tools. It is fast, efficient and easy to use, saving you valuable time and effort.

    Features laser-guided sighting for IR measurements!
    In the IR mode, you can take temperatures within two meters of the target and scan ducts from further away without a ladder. The laser sighting system guides measurements. The single laser dot indicates the approximate center of the measurement area. The measured area becomes larger with distance.

    Features:
    Use the infrared (IR) thermometer to measure hot, moving, electrically energized and hard-to-reach objects instantly
    Check motors, insulation, breakers, radiant heating, pipes, corroded connections and wires plus scan ducts in the ceiling from the floor without a ladder
    Handy Velcro pipe probe included for superheat and sub-cooling contact measurements
    Or plug in your own industry-standard K-type thermocouple probes and get the most out of your tool investments
    IR thermometer for quick measurements up close or at a distance, without a ladder
    Compatible with all standard mini-connector K-type thermocouples
    Velcro pipe probe for superheat, sub-cooling or other contact and ambient measurements
    Single-point laser sighting
    Temperature range optimized for HVAC/R applications
    Easy emissivity adjustment for measuring pipes and ducts more accurately
    Lightweight (only 340 grams (12 ounces) and portable
    Very easy to use
    Efficient – no need to shut down equipment when making IR measurements
    MIN, MAX and DIF temperature readings help you quickly identify problems
    Scan large areas or small objects quickly and efficiently
    HVAC/R measurement guide included to maximize your productivity

    Specification Summary:
    Temperature: -40 to 1022°F (-40 to 550°C)
    Display Resolution: 0.1°F (0.1°C) of reading
    D:S (Distance to spot size): 12:1
    Easy Emissivity Selector: Adjustable with three settings:
    Low (0.3), Medium (0.7). High (0.95)
    Display Accuracy
    Assumes ambient operating temperature of 73°F (23°C) to 77 °F(25°C)]: ±1.0 % of reading ±1 % of reading or ±2°F (±1°C), whichever is greater below 32°F/0°C, ±2°F (±1°C) ± 0.1°/1°
    Response Time: 500 mSec (95 % of reading)
    Repeatability: ±0.5 % of reading or ±2°F (±1°C), whichever is greater
    Spectral Response: 8 µm to 14 µm
    Laser Sighting: Single point laser
    Laser Shutoff: Laser turns off above ambient temperature of 104°F (40°C)
    Laser Power: Class 2(II) operation; Output less than 1 mW wavelengh 630-670 nm
    Relative Humidity: 10 to 90 % RH non-condensing, at less than86°F (30°C)
    Power: 2 AA batteries (alkaline or NiCD)
    Battery Life: 12 hours
    Display Hold: 7 seconds
    Backlit Display: Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options
    Warranty: 2 years
    Operating Temperature: 32 to 120 °F (0 to 50 °C)
    Storage Temperature: -25 to 150 °F (-20 to 65 °C)
    Thermocouple Type K Mini Adapter Input: Yes, compatible with industry standard K type probes with mini-connector.
    Thermocouple Type K Velcro Pipe Probe: Yes, with a temperature range of 32 to 212°F (0 to 100°C) and accuracy of ±4°F (±2.2°C)



    Fluke 566 $660.00

    Fluke 566


      GST inclusive price for Australian Customers is AUD$726.00

      Remove from Cart Add to Cart


    Features & Applications:
    With a simple, 3-button on-screen menu interface (in 6 languages), the Fluke 566 Infrared and Contact Thermometer makes even complex measurements easy. Quickly navigate advanced features to adjust emissivity, start data logging, or turn on and off alarms - with just a few pushes of a button. It also has a rugged, easy-to-use, ergonomic design, which allows it to stand up to tough industrial, electrical and mechanical environments.

    Features:
    Measure -40 °C to 650 °C/-40 °F to 1202 °F
    Easily access advanced features with the soft-key buttons and dot-matrix display
    Measure smaller objects from further away, with a distance-to-spot ratio of 30:1
    Compatibility with all standard miniconnector Type-K thermocouples allow you to preserve your thermocouple investments
    Confidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table
    Capture multiple points of data (up to 20), for downloading and recalling later
    Easily adapt to lighting conditions with 2 levels of backlight
    Audible and visual alarms instantly alert you to measurements outside of your set limits
    Quickly identify problems with the MIN, MAX, AVG, and DIF functions
    Make contact thermometer measurements right away with the included Type-K thermocouple bead probe
    Confidently troubleshoot equipment with 1 % measurement accuracy
    Versatile interface with 6 languages from which to choose (English, Spanish, French, German, Portuguese and Simplified Chinese)
    Includes:
    Thermocouple K bead probe
    Durable hard case
    2 AA batteries
    Getting Started guide in 6 languages
    User’s Manual on CD in 6 languages
    2-year warranty

    Specification Summary:
    Infrared Temperature Range: -40 °C to 650 °C (-40 °F to 1202 °F)
    Infrared Accuracy: less than 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F);
    greater than 0 °C (32 °F): ± 1 % or ± 1.0 °C (± 2.0 °F), whichever is greater
    Display Resolution: 0.1 °C / 0.1 °F Infrared Spectral Response: 8 µm to 14 µm
    Infrared Response Time: less than 500 msec
    Thermocouple Type-K Input Temperature Range: -270 °C to 1372 °C (-454 °F to 2501 °F)
    Thermocouple Type-K Input Accuracy:
    -270 °C to -40 °C: ± (1 °C + 0.2 °/1 °C) (-454 °F to -40 °F: ± (2 °F + 0.2 °/1 °F
    -40 °C to 1372 °C: ± 1 % or 1 °C (-40 °F to 2501 °F: ± 1 % or 2 °F), whichever is greater
    D:S (Distance to measurement spot size: 30:1
    Laser Sighting: Single-point laser less than 1 mw output Class 2 (II) operation, 630 nm to 670 nm Minimum Spot Size: 19 mm
    Emissivity Adjustment: By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
    Data storage w/ Date/Time Stamp: 20 points
    PC Interface and Cable:
    None Hi/Low Alarms: Audible and two-color visual
    Min/Max/Avg/Dif: Yes
    Display: Dot matrix 98 x 96 pixels with functions menus
    Backlight: Two levels, normal and extra bright for darker environments
    Trigger Lock: Yes
    Switchable Celsius and Fahrenheit: Yes
    Power: 2AA/LR6 batteries
    Battery Life: If used continuously: laser and backlight on, 12 hours; laser and backlight off, 100 hours
    Operating Temperature: 0 °C to 50 °C (32 °F to 122 °F)
    Storage Temperature: -20 °C to 60 °C (-40 °F to 140 °F)
    Bead Thermocouple Type-K Range: -40 °C to 260 °C (-40 °F to 500 °F)
    Bead Thermocouple Type-K Accuracy: ± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F), typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)



    Fluke 568 $870.00

    Fluke 568


      GST inclusive price for Australian Customers is AUD$957.00

      Remove from Cart Add to Cart


    Just when you thought advanced IR temperature measurement should be easier, Fluke meets the demands of it's customers with this new line of Thermometers. With a straight-forward user interface and soft-key menus, the Fluke 568 make even complex measurements easy. Quickly navigate and adjust emissive, start data logging, or turn on and off alarms, with just a few pushes of a button. With a rugged, easy-to-use, ergonomic design, the Fluke 568 can stand up to tough industrial, electrical, and mechanical environments

    Features
    Measure -40 °C to 800 °C/-40 °F to 1472 °F
    Easily access advanced features with the soft-key buttons and graphical display
    Measure smaller objects from further away, with a distance-to-spot ratio of 50:1
    Compatibility with all standard mini-connector K-type thermocouples allows you to preserve your thermocouple investments
    Confidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table
    Capture up to 99 point of data, for downloading and recalling later
    Easily trend and analyze data with included FlukeView® Forms software
    See your data right away without leaving the site, using the USB and your laptop for "Hands-free" data logging
    Confidently troubleshoot equipment with 1 % measurement accuracy
    Versatile interface with six languages from which to choose

    Specifications
    Infrared temperature range : -40 °C to 800 °C
    Infrared accuracy: Less than 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F) , greater than 0 °C (32 °F): ± 1 % or ± 1.0 °C (± 2.0 °F), whichever is greater
    Display resolution 0.1 °C / 0.1 °F
    Infrared spectral response: 8 µm to 14 µm
    Infrared response time: Less than 500 msec
    Thermocouple Type-K input temperature range: -270 °C to 1372 °C (-454 °F to 2501 °F)
    input accuracy -270 °C to -40 °C: ± (1 °C + 0.2 °/1 °C) (-454 °F to -40 °F: ± (2 °F + 0.2 °/1 °F)) -40 °C to 1372 °C: ± 1 % or 1 °C (-40 °F to 2501 °F: ± 1 % or 2 °F), whichever is greater
    D:S (distance to measurement spot size) 50:1
    Laser sighting Single-point laser less than 1 mw output Class 2 (II) operation, 630 nm to 670 nm
    Minimum spot size 19 mm (0.75 in)
    Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
    Data storage with Date/Time stamp 99 points
    Hi/Low alarms Audible and two-color visual Min/Max/Avg/Dif Yes
    Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
    Storage temperature -20 °C to 60 °C (-40 °F to 140 °F)
    Bead thermocouple Type-K Range -40 °C to 260 °C (-40 °F to 500 °F) accuracy ± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F), typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)
    Display Dot matrix 98 x 96 pixels with function menus
    PC Interface and cable USB 2.0 with FlukeView® Forms software
    Backlight Two levels, normal and extra bright for darker environments
    Trigger lock Yes
    Switchable Celsius and Fahrenheit Yes
    Power 2 AA/LR6 Batteries USB when used with a PC
    Battery life If used continuously: laser and backlight on,12 hours; laser and backlight off, 100 hours